Electrical Trouble Shooting Guide Table
Voltage while not runningAmps No LoadAmps Under LoadVoltage under loadOperationPossible solution
230-240V4-5A9-10A220V+This within normal range
230-240V9-12A15-17A220V+Start capacitor is stuck onReplace start capacitor
230-240V15A+20A+200V+Motor is burnt outReplace motor
230-240V4-5A11-15A220V+Diamonds are too aggressive or difficult glueSelect diamond with more segments / working half on the glue
230-240V4-5A11-15ALess than 220VPower lead is too long and/or poor qualityImprove power source; shorter lead or more copper (4mm2)
Less than 230V4-5A11-15AWell below 220VPower source is poor (site power or generator)Improve power source; try another power point